Posted in

Can Articulated Boom Lifts be used in cold weather?

Hey there, Articulated Boom Lift

Let’s cut to the chase: if you’re a contractor, facilities manager, or anyone who’s had to do work at height when the wind’s biting and the ground’s covered in frost, you’ve probably wondered this: Can I actually use my articulated boom lift out in the cold? I’m gonna be straight with you here— I’m not some suit in an office writing textbook answers. I’m the guy who’s fielding calls at 7 a.m. in January from job sites in northern Ohio, Canada, and upstate Maine, panicking because their old lift died mid-window installation. So I’ve seen both the wins and the fails when it comes to cold weather and boom lifts.

First off, let’s get one thing out of the way: articulated boom lifts— the ones with that bendy arm that lets you reach around obstacles, right? They weren’t exactly built for tundra conditions. But that doesn’t mean you can’t use ’em when the temp drops below freezing. The key here is knowing what breaks in cold, and what we (suppliers like me) have designed or retrofitted to fix those issues.

Let’s start with the engine, because that’s where 90% of cold-related lift problems happen. You know how your car sputters and won’t start when it’s 15 degrees out? Same with a boom lift— especially if it’s a diesel model, which most construction lifts are. Diesel gel is the big culprit here. When temps hit around 32°F (0°C) and drop, the paraffin wax in diesel fuel starts to solidify, clogging the fuel lines and filters. I’ve had a guy last winter in Minneapolis call me screaming because his lift’s engine died halfway through repairing a streetlight, and when we got there, the fuel line was gunked up like a old candle wick. That’s preventable, though. Most of the new lifts we sell come with fuel heaters now— little electric elements that warm the fuel lines before you crank the engine, so it stays liquid even when it’s 0°F (-18°C). If you’ve got an older lift, you can add an auxiliary fuel heater for a couple hundred bucks, and it’s a game-changer.

Then there’s the battery. Lead-acid batteries hate cold weather. The chemical reaction that makes electricity slows way down when it’s freezing, so your battery might have 12 volts in the garage, but only 5 when you drag it out to the job site. I’ve seen people crank their lift for 10 seconds, then wonder why it dies— their battery’s frozen, basically. Here’s the trick: keep the lift battery indoors when it’s not in use. Don’t leave it parked outside overnight in -20°F. Also, if you’re using it consistently, the battery stays warm just from being charged, so that’s less of an issue, but if you’re working a split shift (like 2 hours in the morning, 2 hours at night), swap the battery out with a warm one, or get a battery blanket. Yeah, it’s a little extra hassle, but way better than being stuck 30 feet up with a dead lift.

Now, the parts you don’t see— the hydraulic system. Hydraulic fluid’s the lifeblood of a boom lift, right? It moves that arm up, down, sideways, everything. Standard hydraulic fluid turns thick as molasses in cold temps. If you try to extend the arm when the fluid’s frozen solid, you’ll either blow a seal or strip a motor— and that’s a $2,000+ repair bill, easy. So what do we do about that? We specify cold-weather hydraulic fluid for all our lifts when someone’s renting or buying for winter work. That fluid is thinner at low temps, so it flows smoothly even in 10°F weather. Also, let the lift idle for 5-10 minutes before you start moving the arm. Yeah, it feels like wasted time, but that gives the hydraulic system a chance to warm up and the fluid to get moving. I’ve seen guys skip that step just to “save time” and end up waiting 3 hours for a repair tech. Not worth it.

What about the operator’s part? The controls, the platform, the mobility. A lot of people don’t think about this, but when it’s cold, metal gets slippery. The platform floor— if it’s a standard steel grid, that’s coated in ice or frost in winter, which is a slipping hazard. Also, the control levers and joysticks might be stiff when it’s cold, so you have to apply more pressure, which can lead to mistakes. Here’s what we recommend: add non-slip rubber matting to the platform (the industrial stuff that works in snow and ice), and keep a can of silicone lubricant in the toolbox to spray on the control levers every few days. Also, remind operators to wear gloves that aren’t bulky— like thin, insulated work gloves— so they can feel the controls. I’ve had a couple near-misses where an operator was wearing big, puffy gloves and didn’t realize he was extending the arm too far. Stupid, but avoidable with a little prep.

Wait, but what about the lift’s structure? Is metal even safe in cold weather? Some people worry about metal becoming brittle when it’s really cold. To be clear, the steel we use for boom lift arms is alloyed specifically for construction, so it doesn’t get brittle in temps way below zero. I’ve tested this myself— we took an old articulated boom lift arm and stuck it in a industrial freezer at -40°F for 72 hours, banged on it with a sledgehammer, and it didn’t crack. So that’s a myth. The structure’s fine, as long as you’re not dropping something heavy on it, obviously. The only exception is if the lift has been sitting outside in subzero weather for months without being used— but even then, a quick inspection for cracks or rust (which becomes more brittle in cold) is all you need.

Now, let’s talk about real-world use cases, because that’s what matters. I had a customer in Toronto last year who used our lifts for window installation on a skyscraper all through December and January, when temps were averaging 10°F (-12°C). He said the only time he had issues was when he forgot to turn on the fuel heater one morning— the engine sputtered for 2 minutes, then ran fine. Another guy in Alaska uses our lifts to maintain ski resort chairlifts in February, when it’s -25°F. He swears by the cold-weather hydraulic fluid, and he changes it every year in October, so it’s ready before the first freeze. The only people who have problems are the ones who try to use their old, unmodified lift like it’s a summer-only machine. Don’t do that.

Wait, what about electric boom lifts? A lot of people ask about those, because they’re quieter and more eco-friendly. Do they work in cold weather? Yeah, but they have their own issues. Electric motors don’t mind cold, but the lithium-ion batteries? Same as lead-acid— they lose capacity in cold. A battery that gives you 8 hours of run time in 70°F might only give you 4 hours in 20°F. So if you’re using an electric lift in cold, you need a bigger battery, or plan for extra charges. Also, if you’re charging it outside in freezing temps, the charger needs to be rated for cold weather too— regular chargers might not work when it’s below 32°F. I usually tell people who need electric lifts for winter work to go with a hybrid model— runs on electric when you’re inside or quiet zones, switches to gas (or diesel) when you need more power in the cold.

Okay, let’s get to the mistakes I see all the time, because this is where most guys go wrong. First, not prepping the lift for cold. I can’t tell you how many times someone has called me in a panic because they brought their lift out on a job in November and didn’t switch to cold-weather fluid. That’s like using summer oil in your truck in January— it’s gonna cause problems. Second, parking the lift outside overnight without any protection. Even if it’s just covered with a tarp, that’s way better than leaving it exposed to wind and frost. Third, rushing the startup. I mentioned this earlier, but it bears repeating— don’t crank the engine for 2 seconds and take off. Let it idle, let the systems warm up, or you’re gonna have a bad time. Fourth, not inspecting tires. Cold temps make tire pressure drop, and low pressure on ice is a recipe for sliding. Check your tire pressure every morning, even if it was fine the night before.

Now, what about safety? I know, safety’s the big one when you’re 50 feet up in the cold. The good news is, if you follow the steps I laid out, articulated boom lifts are just as safe in cold weather as they are in 80°F. The hazards aren’t the lift itself— they’re operator error and lack of prep. For example, if you don’t warm up the hydraulic system and try to move the arm fast, you could have a control malfunction, which would be dangerous. Or if your battery dies mid-lift, you’re stuck there until someone comes to rescue you, and that’s not fun in subzero temps.

Here’s the thing: I started in this industry because my dad ran a small construction company, and he was always having problems with lifts in bad weather. I didn’t want people to be stuck, so I made it my job to know everything about how these machines work in all conditions. So when someone asks me, “Can I use my articulated boom lift in cold weather?” my answer isn’t a flat yes or no. It’s: “Yes, as long as you prep it right, use the right fluids, and take 10 extra minutes to do the checks before you start.”

At the end of the day, you don’t have to put your project on hold just because it’s cold. Whether you’re finishing a residential deck in Minnesota, repairing power lines in Canada, or maintaining a warehouse in New England, there’s a way to make boom lifts work for you when the temps drop. And if you don’t want to deal with the hassle of retrofitting an old lift, or figuring out which parts you need, I’m here to help. I can tell you exactly what modifications your model needs, or even set you up with a lift that’s already tested and ready for cold-weather work, no guesswork involved.

Don’t waste another morning panicking because your lift won’t start, or paying for costly repairs that could’ve been avoided. Whether you need to buy a new lift, rent one for a winter project, or just ask questions about prepping what you already have, reach out. Let’s get your job done, even when the weather’s not perfect.

Scissor Lift References

  1. Occupational Safety and Health Administration (OSHA). Guidelines for Work Platforms in Cold Weather Conditions. Retrieved from OSHA Technical Manual, Section 3, Chapter 5.
  2. International Organization for Standardization (ISO). Standard 18878: Mobile elevating work platforms – Articulated boom lifts.
  3. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Cold-Weather Equipment Operation Guidelines for Construction Machinery.

Mantall Heavy Industry Co., Ltd.
Mantall Heavy Industry Co., Ltd. is well-known as one of the leading articulated boom lift manufacturers and suppliers in China, featured by quality products and good service. Welcome to buy discount articulated boom lift made in China here from our factory. For pricelist and quotation, contact us now.
Address: NO.62, Binhai Avenue, Binhai Industrial Park, Qidong City, Jiangsu Province, China
E-mail: Gloria@mantall.com
WebSite: https://www.mantallawp.com/