Posted in

What is the turn – on time of a Switch Tube?

If you’ve ever worked with power electronics, industrial control systems, or even high-end audio equipment, you’ve likely encountered switch tubes—those unsung components that make it possible to control the flow of electricity in everything from variable frequency drives to power supplies. But if you’re a design engineer, a procurement specialist, or a hobbyist looking to optimize your projects, one question that pops up again and again is: what exactly is the turn-on time of a switch tube, and why does it matter so much? As a supplier of switch tubes with over 12 years in the game, I’ve spent countless hours walking engineers through this exact question, troubleshooting delays, and helping folks pick the right components for their needs. Today, I want to break this down in plain, practical terms—no overly jargon-heavy nonsense, just what you need to know to get your projects running smoothly. Switch Tube

First, let’s start with the basics. A switch tube (most commonly a MOSFET or an IGBT, depending on power and voltage requirements) is essentially an electronic switch. When you apply a control signal (a gate voltage for MOSFETs, a gate current pulse for IGBTs) to its terminal, it toggles from an “off” state (where it blocks current) to an “on” state (where it allows current to flow). Turn-on time is the exact duration between the moment that control signal reaches the switch’s gate and the moment the switch is fully conducting, at its lowest possible on-resistance (or saturation voltage, for IGBTs). That’s the simple definition, but the devil is in the details—and that’s where most people run into trouble.

Let me explain with a real-world example, something I see every month when talking to engineers designing solar inverters. Suppose you’re building a 10kW solar inverter that switches DC power to AC at 20kHz. If your switch tube has a turn-on time of 100 nanoseconds (ns), that’s 0.0000001 seconds. At first glance, that sounds tiny—until you realize that at 20kHz, each switching cycle is 50,000 ns long. Wait, 100 ns is only 0.2% of the cycle, right? That can’t matter, can it? But here’s the catch: if you miscalculate turn-on time, that tiny delay can cause overlapping conduction between the high-side and low-side switch tubes in your inverter’s H-bridge. For a millisecond at a time, both switches are partially on, creating a short circuit across your DC bus—burning out fuses, damaging transistors, and even shutting down the entire system. I’ve had three different customers in the last year come to me with exactly this problem, all because they looked at a datasheet and assumed turn-on time was a single number, not a set of delays.

Let’s pull back the curtain on what turn-on time actually consists of, because datasheets don’t always spell this out clearly. When you send that gate signal, it doesn’t just instantly flip the switch. There are four distinct phases of turn-on, all adding up to the total turn-on time:

  1. Gate Charge Delay Time (td(ON)): This is the time between when the gate signal reaches its threshold voltage and when the switch starts to actually conduct current. Think of it like flipping a light switch: you move your finger to the lever, but it takes a split second for the lever to start moving. For most small-signal MOSFETs, this delay is just a few ns, but for high-power IGBTs used in industrial drives, this can stretch to hundreds of ns. The delay comes from the capacitor-like gate structure of the switch tube—you have to charge the gate capacitance (Ciss) up to the point where the channel starts to form, and that takes time, based on how much current your gate driver can supply. That’s a key point: turn-on time isn’t just a property of the switch tube alone—it’s dependent on your gate driver circuit, too. A weak gate driver that can’t push enough current to charge the gate quickly will make turn-on time longer, no matter how fast the switch is rated.

  2. Current Rise Time (tr): Once the channel starts forming, the next phase is when the switch’s current starts to climb from its leakage current (off-state) up to its full on-state current. This is like the light switch moving from the “halfway” position to fully on. For MOSFETs, this is driven by how quickly the gate voltage can rise above the threshold and into the flat region where the on-resistance is set. For high-power IGBTs, this can be a bit slower because of the minority carrier injection that happens as the current rises. In my experience, this is the phase that causes most of the trouble in fast-switching applications, because if tr is too slow, you’re not getting the full benefit of a high-frequency switch, leading to switching losses that waste energy and heat up your system.

  3. Voltage Drop Time (fv): Wait, did I miss one? No, actually, after the current rises to its full level, the voltage across the switch (Vds for MOSFETs, Vce for IGBTs) drops from its off-state level (equal to your supply voltage) down to the on-state level. A lot of datasheets lump this into the rise time, but it’s a separate phase that adds a bit more to total turn-on time. For low-voltage, low-power switches, this is negligible, but for 1200V IGBTs used in wind turbines, this can add 20-30% to the total turn-on time, especially if your gate driver isn’t optimized to pull the voltage down quickly.

  4. Tail Time (for IGBTs only): Okay, one extra thing specific to IGBTs, because they’re bipolar devices. When you turn an IGBT off, there’s a period where the current doesn’t drop immediately—it has a “tail” because of minority carriers stored in the device’s structure. Wait, no—wait, that’s turn-off time, but it does have a side effect on turn-on. If you turn an IGBT on before those stored carriers are fully gone from the last cycle, you get a surge in current when the new turn-on happens. That’s called turn-on tail time overlap, and it’s a huge source of losses in high-power applications. I had a wind turbine manufacturer come to me two years ago; their inverters were overheating 20% faster than expected, and the problem was that they were choosing IGBTs based on turn-on time alone, not accounting for the tail time of adjacent devices in their array.

Now, let’s talk about how datasheets list turn-on time, because this is where most people get confused. You’ll see a value labeled tON, usually in ns or microseconds (µs), with a test condition attached: typically, Vds = 400V, Id = 10A, gate resistance (Rg) = 10Ω, and gate drive voltage = 10V. Those test conditions are not arbitrary—they’re standardized to make comparisons between switch tubes fair. But here’s the catch: if your actual circuit doesn’t match those test conditions, the turn-on time will be different. Let’s say you’re using a MOSFET in a 24V circuit, not 400V, with a gate resistance of 50Ω instead of 10Ω. Your turn-on time will be longer than the datasheet’s listed tON, because the lower Vds means a slower charge process, and the higher Rg means your gate driver is charging the gate capacitance more slowly.

I can’t tell you how many times I’ve gotten an email from a customer saying, “Your switch tube’s turn-on time is listed as 50 ns, but my scope is measuring 120 ns—why is that?” Almost every time, the problem is that they didn’t account for their gate resistance or their actual operating voltage. That’s why, as a switch tube supplier, we always include a “derating curve” for turn-on time on our product pages, showing how it changes with Vds, Id, and Rg. We also have an application engineering team that will work with you to adjust your gate driver if you need to hit a specific turn-on time. For example, if you’re designing a high-frequency DC-DC converter that needs turn-on time under 80 ns, we can suggest a gate driver that supplies 2A of current instead of 0.5A, cutting the turn-on delay by 30-40 ns without having to switch to a more expensive high-speed device.

Now, why does turn-on time matter, beyond avoiding short circuits? Let’s talk about power losses, because that’s the big one for efficiency. Every time a switch turns on and off, it dissipates some power—called switching loss. The faster the turn-on time, the less time the switch is operating in that linear region (where both voltage and current are high at the same time), so the lower the switching loss. For a 10kW solar inverter, switching losses can account for 5-10% of total energy loss over a year. Multiply that by thousands of inverters, and that’s millions of dollars in wasted energy. A customer in the automotive sector recently switched to our high-speed MOSFETs with 45 ns turn-on time, and they saw a 7% improvement in the efficiency of their electric vehicle on-board charger—enough to meet new EU emissions standards without adding extra battery weight.

But it’s not just efficiency. For high-frequency applications, turn-on time directly limits how fast you can switch. If your turn-on time is 100 ns, you can’t run your switching cycle faster than about 5MHz—because you need at least twice the turn-on time to avoid overlapping conduction between devices. If you try to push 10MHz with a 100 ns turn-on time, you’ll get a dead short that blows your switch in minutes. I’ve seen hobbyists and small startups make this mistake all the time: they buy cheap, low-quality switch tubes rated for high current, but their turn-on time is hundreds of ns, so they can’t get the high frequency they need for a compact design. That’s where our team steps in—we’ll match their frequency requirements to the right switch, and suggest any gate driver adjustments they need to get the turn-on time they want without overspending.

Another common question: is faster always better? Not exactly. There’s a trade-off. Faster turn-on time usually means a higher gate capacitance, which means more energy is needed to charge the gate every cycle. For low-power, battery-powered applications, that can increase power draw from the control circuit, reducing battery life. We had a customer designing a portable medical device, for example; they needed very fast turn-on for a precision power supply, but they only had a tiny 3V gate supply. A fast-switching MOSFET would have required too much gate charge, draining the battery. So we suggested a medium-speed switch with optimized gate design, giving them a 70 ns turn-on time without the extra gate charge, keeping their battery life at 5 years instead of 2.

So, how do you measure turn-on time if you’re designing a project? The best way is with an oscilloscope, set up to measure the gate signal, the drain-source voltage (or collector-emitter voltage for IGBTs), and the drain current. To get an accurate reading, you have to set the trigger on the rising edge of the gate signal, then measure the time from when that rising edge crosses your gate threshold voltage (usually 1.5V for MOSFETs) to when the current reaches 90% of its full on-state value, and the voltage drops to 10% of its off-state value. That matches the standardized test conditions, so your measurement will line up with the datasheet. If you’re not comfortable setting up that test, our application engineers can help—we offer free sample kits with datasheet and typical application notes, and we can walk you through the measurement process over a call.

Let’s wrap this up with some key takeaways, because I know it’s easy to get lost in all the details. First, turn-on time is not a single number—it’s a sequence of delays, dependent on both the switch tube’s design and your gate driver circuit. Second, datasheet values are given for standard test conditions, so always derate them for your actual operating voltage, current, and gate resistance. Third, turn-on time matters for efficiency, switching frequency, and avoiding destructive short circuits. Fourth, faster isn’t always better—balance turn-on speed with gate charge and power draw for your specific application.

If you’re working on a project where turn-on time is critical—whether it’s a solar inverter, an electric vehicle charger, a medical device, or even a high-end audio amplifier—we’re here to help. Our team has 12 years of experience in custom switch tube selection, gate driver design, and troubleshooting switching performance. We don’t just sell components; we partner with engineers to make sure their projects run as efficiently and reliably as possible.

To discuss your switch tube needs and get a quote tailored to your turn-on time requirements, feel free to reach out to our team directly. We can provide samples, application notes, and real-world performance data to help you make the right choice for your project.

Capacitor References

  1. Power MOSFET Basics: Understanding Switching Parameters, Texas Instruments, 2022
  2. IGBT Turn-On and Turn-Off Characteristics, Infineon Technologies, 2021
  3. Switching Loss Calculations for High-Frequency Power Electronics Applications, International Rectifier Application Note AN-900, 2020
  4. Gate Driver Design Considerations for MOSFET and IGBT Circuits, ON Semiconductor, 2023

Jingdezhen Wanping Electric Co., Ltd.
As one of the most professional switch tube manufacturers and suppliers in China, we also support customized service. We warmly welcome you to buy high quality switch tube made in China here and get pricelist from our factory. For price consultation, contact us.
Address: Zhangshukeng, Jingdezhen City, Jiangxi Province.
E-mail: jdzwpdq0815@163.com
WebSite: https://www.cewpdq.com/